9264.950
9264.952
9264.960
|
Test station for checking personnel grounding connection of wrist straps and footwear, according to the IEC 61340-5-1.
Separate testing of left and right shoe; the test is executed at 50V or 100V to provide more accuracy.
A relay output allows access to ESD Protected Area.
Internal battery supplied 9V or external 9Vdc.
ISO9000 traceable certificate is included.
The personnel grounding test station can work in 4 modes:
1) Simultaneous measurement of wrist straps and footwears.
2) Wrist straps only measurement
3) Footwears only measurement
4) HandsFree mode (if the serial measure of the two footwears pass the test then the internal relay enables the gate to the EPA area)High efficiency led displays.
Fully programmable by keyboard.
|
Low limit |
High limit |
Wrist strap
|
0 – 750KΩ
(selectable) |
10MΩ – 35MΩ
|
Footwear
|
0 – 100KΩ
(selectable) |
10MΩ – 35MΩ – 70MΩ – 100MΩ – 200MΩ
(selectable for standard version IEC 61340-5-1)
or
1GΩ for the Atex special version |
Standard version for IEC 61340-5-1 |
|
9264.950*: Personnel Grounding Test Station wall mounted including: Wristlab-II instrument, footplate and yellow panel.
9264.952*: Personnel Grounding Test Station on stand-up support including: Wristlab-II instrument, footplate, yellow panel and stand-up support
9264.955: Instrument recalibration (ISO9000 Traceable certificate is supplied)
9264.960: Wristlab-II instrument |
* Add to code: I (Italian), F (French), E (English), D (German), H (Hungarian), S (Spanish) |
Atex special version |
|
To request special version with the upper threshold of shoes set fixed at 1GΩ add to code the suffix 1G:
9264.950.1G*: Personnel Grounding Test Station wall mounted including: Wristlab-II instrument, footplate and yellow panel.
9264.952.1G*: Personnel Grounding Test Station on stand-up support including: Wristlab-II instrument, footplate, yellow panel and stand-up support
9264.955: Instrument recalibration (ISO9000 Traceable certificate is supplied)
9264.960.1G: Wristlab-II instrument
|
* Add to code: I (Italian), F (French), E (English), D (German), H (Hungarian), S (Spanish) |
|
|
Calibration Unit
It’s a resistance decade box made specifically for the calibration of the ESD Test Station (9264.960 Wristlab-II, 9264.925 Test Station EVO, 9265.030 Wristlab and IEC 61340-5-1 compatible testers)
Range: 10Ω-110MΩ(resolution 10Ω)
Tolerance: 1%
Power: 1W for resistors up to 4MΩ – 0.5W for resistors from 10MΩ to 40MΩ
Operative Voltage: 250Vac max
Dimensions: 14,7 x 11,7 x 5,5cm
Weight: 320gDetailed instruction manual for calibration procedures of the IEC61340-5-19264.980: Calibration Unit for ESD testers cables and adapters included |